摘    要:LaB_6阴极与其他类型阴极相比具有电子发射电流密度大等优点,已广泛用于电推进、高发射密度电子枪等产品。为了研究LaB_6空心阴极中毒特性、识别LaB_6空心阴极主要失效模式,分别对LaB_6空心阴极暴露大气后性能变化特征和引起性能变化的原因进行了研究。结果表明:LaB_6空心阴极在暴露大气后表面吸附大量中毒气体,出现了发射体表面逸出功增加、发射体短期中毒现象。此时空心阴极的放电电压和阴极顶温度均有所上升,经过短期工作后放电电压和阴极顶温度均恢复初始状态。但LaB_6空心阴极严重中毒后,并不能通过加热和离子轰击方式去除表面生成的氧化物。因此,可以在实验过程中通过监测空心阴极的阴极顶温度和阳极电压变化间接表征空心阴极发射体状态。

关 键 词:LaB6空心阴极  寿命实验  氧中毒  阴极顶温度
收稿时间:2019/1/11 0:00:00

Poisoning characteristics of LaB6 hollow cathode
YANG Wei,ZHANG Tianping,LONG Jianfei,GUO Ning,LIU Mingzheng,GU Zengjie.Poisoning characteristics of LaB6 hollow cathode[J].Journal of National University of Defense Technology,2020,42(4):93-97.
Authors:YANG Wei  ZHANG Tianping  LONG Jianfei  GUO Ning  LIU Mingzheng  GU Zengjie
Institution:National Key Laboratory of Science and Technology on Vacuum Technology & Physics, Lanzhou Institute of Physics, Lanzhou 730000, China;College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410073, China;School of Nuclear Science and Technology, University of South China, Hengyang 421001, China
Abstract:Compared with other cathodes, LaB6 cathode has the advantage of high electron emission current density, and has been widely used in electric propulsion, high emission density electron gun and other products. In order to analyze the poisoning characteristics of the LaB6 hollow cathode and identify its failure mode, the performance change features and reasons of LaB6 hollow cathode exposed to atmosphere were studied. The results show that the LaB6 hollow cathode adsorbs a great deal of poisonous gas on the surface of the emitter during exposure to the atmosphere, and while the work function from the emitter surface increases, the emitter appears short-term poisoning phenomenon. The discharge voltage and hollow cathode plate temperature are increased, and the discharge voltage and cathode top temperature are restored to the initial state after short-term operation. However, if the poisoning phenomenon of LaB6 hollow cathode is serious, the oxide generated on the surface can not be removed by heating and ion bombardment. Therefore, the emitter state of hollow cathode can be indirectly characterized by monitoring the change of cathode temperature and anode voltage during the test.
Keywords:LaB6 hollow cathode  life test  oxygen poisoning  orifice plate temperature
本文献已被 CNKI 等数据库收录!
点击此处可从《国防科技大学学报》浏览原始摘要信息
点击此处可从《国防科技大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号