首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Research on design and firing performance of Si-based detonator
Institution:Science and Technology on Applied Physical Chemistry Laboratory, Shaanxi Applied Physics-Chemistry Research Institute, Xi''an 710061, China
Abstract:For the chip integration of MEMS (micro-electromechanical system) safety and arming device, a miniature detonator needs to be developed to reduce the weight and volume of explosive train. A Si-based micro-detonator is designed and fabricated, which meets the requirement of MEMS safety and arming device. The firing sensitivity of micro-detonator is tested according to GJB/z377A-94 sensitivity test methods: Langlie. The function time of micro-detonator is measured using wire probe and photoelectric transducer. The result shows the average firing voltage is 6.4 V when the discharge capacitance of firing electro-circuit is 33 μF. And the average function time is 5.48 μs. The firing energy actually utilized by Si-based micro-detonator is explored.
Keywords:MEMS safety and arming device  Initiating device  Si-based detonator  Firing sensitivity  Function time
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号