Research on design and firing performance of Si-based detonator |
| |
Affiliation: | Science and Technology on Applied Physical Chemistry Laboratory, Shaanxi Applied Physics-Chemistry Research Institute, Xi''an 710061, China |
| |
Abstract: | For the chip integration of MEMS (micro-electromechanical system) safety and arming device, a miniature detonator needs to be developed to reduce the weight and volume of explosive train. A Si-based micro-detonator is designed and fabricated, which meets the requirement of MEMS safety and arming device. The firing sensitivity of micro-detonator is tested according to GJB/z377A-94 sensitivity test methods: Langlie. The function time of micro-detonator is measured using wire probe and photoelectric transducer. The result shows the average firing voltage is 6.4 V when the discharge capacitance of firing electro-circuit is 33 μF. And the average function time is 5.48 μs. The firing energy actually utilized by Si-based micro-detonator is explored. |
| |
Keywords: | MEMS safety and arming device Initiating device Si-based detonator Firing sensitivity Function time |