首页 | 本学科首页   官方微博 | 高级检索  
     


Response of masonry systems against blast loading
Authors:Eid Badshah  Amjad Naseer  Mohammad Ashraf  Tauseef Ahmad
Affiliation:Department of Civil Engineering, UET Peshawar, Pakistan;Electrical Engineering Department, CECOS University of IT&Emerging Sciences Peshawar, Pakistan
Abstract:In this paper eight successive experimental blast tests with an increasing TNT equivalent charge weights ranging from 0.56 kg to 17.78 kg were conducted on unreinforced, ferrocemented overlay masonry and confined masonry walls. The pressure-time history caused by the blast was recorded by pressure sensors installed on the test specimen. The resulting damage pattern was observed during each test. Weak zones in the three systems of masonry were identified. Scaled distances for different damage levels in the three masonry systems were experimentally obtained. The results provide a basis for determining the response of each masonry system against blast loading. Consequently, efficiency of ferrocemented overlay ma-sonry and confined masonry was found established in mitigation against blast loads.
Keywords:Peak over pressure  Pressure sensor  Composition-B  TNT  Scaled distance  Stand-off distance  Charge shape  Confined  Unreinforced  Ferrocemented
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号